Oxa Cube Solo Hyperbaric Oxygen Chamber (HBOT, Single) in use

Oxa Cube Solo Hyperbaric Oxygen Chamber (HBOT, Single)

A single-user steel cabin with a high-transparency acrylic door, built-in comfort interior and a 10 L/min oxygen generator.

Single-user hyperbaric oxygen chamber rated 2.0 ATA, with a steel cabin, high-transparency acrylic door and a 10 L/min oxygen generator.

Commercial-Grade Build for Daily Use
Delivery, On-Site Installation & Setup
Dedicated Operational Staff Protocols & Post-Commissioning Training
Chat on WhatsApp
Direct support from the GreenPulse team
Comprehensive Engineering

Architectural Design & Therapeutic Intent

The Oxa Cube Solo is a single-user hyperbaric oxygen chamber rated at 2.0 ATA. The cabin is made of SPCC carbon steel plate, square steel and ABS, and measures 1900 × 900 × 1950 mm.

The door is a 30 or 40 mm high-transparency acrylic panel. Inside, the cabin is fitted with wall panels, sofa and interior upholstery, air conditioner, lighting, a nasal spray device and an intelligent control panel. A separate oxygen generator supplies 10 L/min at 93% ± 3% concentration.

Working pressure inside the cabin is adjustable from 10 kPa to 50 kPa, with safety systems and dual-screen touch control. This product requires a regulatory check and a trained operator.

Pressurised Cabin with Oxygen Concentrator

A sealed steel cabin is pressurised with filtered air from an oil-free compressor, while a separate PSA oxygen generator supplies the oxygen source.

  • 1Cabin pressurised to the stated ATA rating.
  • 2Controlled boost and release rates (≤ 4 kPa/min up, ≤ 12 kPa/min down).
  • 3PSA oxygen generator at 93% ± 3% concentration.
  • 4Manual relief valve, emergency switch and automatic safety valve.
Hardware Highlights

Engineered Capabilities & Advanced Controls

Multiple Safety Systems

Manual pressure relief valve, emergency switch and automatic safety valve.

Turnkey Tested

Dual-Screen Control

Capacitive touch controls inside and outside the cabin.

Turnkey Tested

Comfort Interior

Fitted with wall panels, sofa and interior upholstery, air conditioner, lighting, a nasal spray device and an intelligent control panel.

Turnkey Tested

Intercom & Lighting

Dual-mode intercom and 12 V LED lighting.

Turnkey Tested

Quiet Operation

Internal noise ≤ 45 dB.

Turnkey Tested

Modular Assembly

Modular build for easier delivery and installation.

Turnkey Tested
Physiological Efficacy

Evidence-Based Biological Benefits

≤ 4 kPa/min

Controlled Pressurisation

Gradual boost and release rates.

≤ 45 dB

Quiet Cabin

≤ 45 dB inside.

Engineering Blueprint

Full Technical Specifications

Cabin Specifications6 Parameters Calibrated

Pressure Rating
2.0 ATA
Working Pressure (inside cabin)
Adjustable 10–50 kPa
Cabin Dimensions
1900 × 900 × 1950 mm
Cabin Material
SPCC carbon steel plate, square steel, ABS
Door
30 / 40 mm high-transparency acrylic
Capacity
1 person

Turnkey Delivery & Included Components

Oxa Cube Solo cabin with interior fit-out
Oxygen generator (PSA)
Oil-free air compressor system
Dual-screen control panel and intercom
Clinical Methodology

Recommended Session Protocols

Optimal Session Time
Set by the qualified operator

Calibrated to maximize therapeutic outcome without triggering biological exhaustion.

Weekly Cadence
Per the operator's programme

Cumulative regenerative benefits compound with consistent weekly integration.

Safety Notice & Contraindications
  • •Hyperbaric chambers must only be installed and operated in line with local regulations, by a trained operator, following the manufacturer's safety procedures.
  • •Not suitable for everyone. A medical professional should confirm that a person is suitable before any session.

Step-by-Step Operator & User Procedure

Pre-Session Checklist

  • Confirm local regulatory requirements are met and the operator is trained.
  • Check the safety valves, emergency switch and intercom before every session.

Session Execution Steps

1
Pre-check

Run the operator's safety checklist and confirm the user is suitable.

2
Session

Pressurise gradually and monitor via the intercom and control panel.

3
Release

Release pressure at the controlled rate before opening the door.

Spatial Architecture

Turnkey Facility Integration

Setting

Longevity & Wellness Centres

A supervised pressurised-cabin service within a wellness menu.

Ready to deploy →
Setting

Clinics (where regulations permit)

Installed and operated only in line with local requirements.

Ready to deploy →
Direct Clarifications

Frequently Asked Questions

2.0 ATA, with working pressure inside the cabin adjustable from 10 to 50 kPa.
Recovery Synergies

Frequently Paired Equipment

Explore full catalog